HotLok® products are specifically designed to control intake airflow in server racks. The award-winning blanking panels are considered the ‘best-fitting’ in the industry.
Blanking Panels – 1U & 2U / Black & White
Designed to effectively seal openings in IT equipment cabinets and control airflow for optimized cooling effectiveness. The HotLok Blanking Panel reduces hotspots and bypass airflow by preventing equipment exhaust air or hot aisle air from migrating to the conditioned air intake stream at the front of the cabinet. HotLok Blanking Panels are available in both 1U and 2U configurations and a choice of traditional black or a more reflective white.
Pass Through Blanking Panels – 1U & 2U
Designed to provide an effective airflow sealing solution when used in conjunction with pullout KVM switches or servers that may be occasionally extracted. Also provides additional rack sealing where cables prevent solid blanking panels from being installed.
This new aluminum and Hybrid Brush Technology panel cost effectively controls airflow and particulates for optimized cooling effectiveness. Lab tested HotLok Pass Through Blanking Panels also perform better than any competitive product. Available in both 1U and 2U configurations.
Blanking Panels with Temperature Strips – 1U & 2U
The HotLok® Blanking Panel is a snap-in blanking panel that seals the rack 29% better than the nearest competitor and helps you identify hotspots within minutes of installation. The cabinet temperatures are indicated in color-coded ranges, depending on location of temperature strip panel. The state-of-the-art technology, designed for both 1U and 2U openings, controls airflow for optimized cooling effectiveness.
HotLok® Blanking Panel with Temperature Strip is Upsite’s latest green solution for energy savings and reducing the carbon footprint of data centers.
Full Rack Blanking Panel Kit – 42U
Designed to seal up to 42U of opening in the server rack, the Full Rack Blanking Panel Kit greatly reduces bypass airflow by eliminating the gaps in the server rack and creating a contained server rack environment. This sealing solution increases usable cooling unit capacity, maximizing the effectiveness and efficiency of your cooling infrastructure.
Full Rack Blanking Panel Kit – 36U
Designed to seal up to 42U of opening in the server rack, the Full Rack Blanking Panel Kit greatly reduces bypass airflow by eliminating the gaps in the server rack and creating a contained server rack environment. This sealing solution increases usable cooling unit capacity, maximizing the effectiveness and efficiency of your cooling infrastructure.
Round 4″ Rack Mount Grommet
Designed to seal 4” (102mm) cable openings in new and existing server rack cutouts to block bypass airflow and maximize cooling system efficiency.
HotLok® Round Rack Mount Grommet, the latest patented thermal management solution is the premium choice for your facility. Its revolutionary sealing technology greatly reduces costly bypass airflow, increasing usable cooling unit capacity, and ensuring maximized efficiency from HVAC equipment.
Upsite Temperature Strip
The HotLok® Temperature Strip is a liquid crystal thermometer with an acrylic self-adhesive backing that quickly and accurately measures the intake air temperature of IT equipment. It indicates whether the air temperature is within acceptable limits based on the standards established by the American Society of Heating, refrigerating, and Air Conditioning Engineers (ASHRAE) and equipment manufacturers. Measurement of equipment intake air temperature is used in the management of all elements of cooling infrastructure such as the number and type of perforated tiles or grates, cooling unit temp set points, and cooling unit airflow volumes.
RAM Kit 45 & 90 Degree Extrusion & Sealing Membranes
Designed to seal gaps between the rail and side of cabinet, the Rack Airflow Management Kit greatly reduces bypass airflow and re-circulation in your cabinets. The Rack Airflow Management Kit increases usable cooling unit capacity, maximizing the effectiveness and efficiency of your cooling infrastructure.